Introduction
The elevator blower is a specialized ventilation unit mounted on top of or within an elevator car to maintain continuous air circulation.
Product Specification
|
Item |
Key Specification |
|
Airflow Output |
250–450 CFM (425–765 m³/h) |
|
Noise Level |
38–45 dB(A) at 1 meter |
|
Electrical Input |
110V / 220V / 380V, 50/60Hz compatibility |
|
Power Consumption |
25–65W (high-efficiency motor) |
|
Static Pressure Capacity |
≤ 60 Pa |
|
Installation Tolerance |
±0.5 mm for ceiling integration |
Technical Performance
|
Model |
Rated Airflow (m³/h / CFM) |
Rated Speed (RPM) |
Noise Level [dB(A)] |
Rated Current (A) / Power (W) |
Recommended Lift Capacity |
|
EB-300A |
320 m³/h / 188 CFM |
1100 |
≤ 42 dB(A) |
0.22 A / 50 W |
≤ 1000 kg (Standard Passenger) |
|
EB-450A |
480 m³/h / 282 CFM |
1250 |
≤ 45 dB(A) |
0.28 A / 65 W |
1050–1350 kg (Commercial) |
|
EB-600H |
620 m³/h / 365 CFM |
1400 |
≤ 48 dB(A) |
0.38 A / 85 W |
≥ 1600 kg (Heavy-Duty / Bed Lift) |

Key Features
Dual-Bearing System: Equipped with Japanese NMB dual-shielded ball bearings rated for 50,000 hours of continuous operation, preventing oil leakage and reducing routine maintenance callbacks.
Reinforced Galvanized Steel Housing: Stamped from 1.5mm rust-resistant galvanized steel sheets to eliminate structural resonance and rattling noises at high RPMs.
Integrated Finger Guards: Heavy-duty chrome-plated steel wire grilles prevent accidental contact with moving parts during routine lift shaft maintenance.
Variable Speed Integration: Built-in multi-tap transformers allow field technicians to toggle between High, Medium, and Low speed settings via terminal jumpers.
Dynamic Balance Precision: Every rotor is dynamically balanced to ISO 1940 G2.5 standards, keeping structural vibration amplitudes below 0.15 mm/s for whisper-quiet lift operation.
OEM/ODM Capabilities
Custom Interface Engineering: Modification of mounting brackets and flange placements within 5 working days based on your 3D CAD/STEP models.
Custom Voltage & Emergency Power: Custom motor windings for non-standard regional power grids, including integrated 24V DC emergency backup power for power outages.
Private Labeling & Laser Etching: Direct on-line laser etching of client logos, custom part numbers, and tracking barcodes on the chassis for OEM brand consistency.
R&D Prototyping Speed: Fully operational functional samples delivered within 14 calendar days via our dedicated engineering workshop to accelerate your project timeline.
Noise Level Tuning (NC/NR): Custom tuning of fan blade frequency profiles to help your lift projects pass strict building acoustic codes and explicit NC/NR noise rating limits.
Quality Control & Compliance
100% On-Line Motor Inspection: Automatic routine testing of every single motor for insulation resistance, dielectric strength, and starting voltage before final assembly.
Acoustic Isolation Testing: Daily sound-pressure tracking conducted inside a semi-anechoic room with an ambient noise floor below 15 dB(A) to verify batch-to-batch consistency.
96-Hour Salt Spray Resistance: Brackets and housings undergo 96-hour ASTM B117 salt spray testing to prevent corrosion and paint peeling in coastal or high-humidity lift environments.
Global Certificate Compliance: Certified under Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, and UL 507 safety standards for electric fans.
Ingress & Flame Protection: Motor housings carry IP23/IP44 ratings against dust and water splashes; all plastic impellers meet UL 94 V-0 self-extinguishing protocols.
Comprehensive QC Traceability: Every shipped fan features a unique QR code linked directly to its specific factory test reports and dynamic balance data sheets.

Supply Chain Support
Minimum Order Quantity (MOQ): Low MOQ of 50 units for standard catalog models, and 200 units for custom engineered OEM batches.
Scale Production Output: Main assembly facility outputs up to 35,000 certified blower units per month to support high-volume contract releases and scheduled drop-ships.
Port Proximity & FOB Delivery: Factory location allows secure FOB delivery to Shanghai or Ningbo container ports within 48 hours of final packing.
Export-Grade Protective Packing: Individual multi-layer corrugated boxes consolidated on ISPM-15 certified heat-treated export wood pallets.
Strategic Buffer Inventory: Rolling stock of 2,000 standard chassis components maintained in-house to fulfill urgent, short-notice emergency orders.
After-Sales Service
24-Month Factory Warranty: Full component replacement or repair covering manufacturing and material defects, valid from the Bill of Lading (B/L) date.
10-Year Spare Parts Lifecycle: Guaranteed long-term availability for critical maintenance parts-including spare impellers, bearings, and capacitors-post-production.
24-Hour Technical Response: Global B2B ticketing system connects your technical team with an application engineer within 24 hours.
Advanced RMA (Pre-Shipment Replacement): Replacement units are dispatched immediately upon claim verification before returning the audited components, minimizing elevator downtime.
FAQ
Q: What elevator cabin sizes is this blower compatible with?
A: Designed for standard passenger cabins ranging from 800×1000 mm to 1600×2400 mm ceiling modules. For non-standard cabins, mounting brackets adjust within ±30 mm tolerance without structural modification.
Q: How long can the blower operate continuously in real applications?
A: Tested for up to 60,000 operating hours under rated load conditions, translating to 7–9 years of service in 12–16-hour daily operation buildings. In residential buildings running 8–10 hours daily, service life extends to 13–17 years.
Q: How is long-term noise performance maintained?
A: Dynamically balanced impellers and wear-resistant bearings limit noise increase to less than +3 dB(A) after 20,000 hours. Field measurements remain stable within 40–48 dB(A) over long operation cycles.
Q: What is the typical installation time per elevator?
A: A trained technician completes full installation in approximately 1.5–2.5 hours per cabin, including wiring, mounting, vibration alignment, and functional testing.
Q: How often does maintenance need to be performed?
A: Basic dust cleaning is recommended every 6–12 months depending on environment. Bearing inspection is required after approximately 25,000 operating hours, with no lubrication needed due to sealed bearing design.
Q: What happens if the blower fails during elevator operation?
A: Ventilation failure does not interrupt elevator operation. Replacement can be completed within 30 minutes through modular plug-in design.
Q: Can it operate under emergency power conditions?
A: Yes, the motor supports low-voltage restart and operates on 24V DC backup systems. Startup torque remains stable at 85% of nominal performance under emergency supply conditions.
Q: What is the actual power consumption in daily use?
A: Average consumption ranges between 28W and 58W depending on speed mode. For a typical elevator running 14 hours daily, annual energy consumption is approximately 140–280 kWh.
Q: Can non-contract buyers get emergency replacement units quickly?
A: A rolling buffer stock of 2,000 standard chassis units is maintained for urgent orders. Non-contract buyers typically receive standard catalog models within 5–7 business days via air freight.
Q: What documentation is available for elevator authority inspections?
A: Every unit ships with a QR-linked factory test report, dynamic balance data sheet, CE Declaration of Conformity, UL 507 certificate, and IP rating test records.
Hot Tags: elevator blower, China elevator blower manufacturers, suppliers, factory, elevator cabin structure, elevator car alarm button, elevator car floor indicator, elevator car handrail support, elevator car LED driver, elevator car top control station